T1 - Numerical investigation of local convective heat transfer coefficients for a walking human model under varying wind directions
AU - Zhou, Qigui
AU - Su, Xiaowen
AU - Yuan, Yanping
AU - Chen, Dengkai
AU - Jiang, Fujian
N1 - Publisher Copyright:
© 2026 Elsevier Ltd
PY - 2026/11/1
Y1 - 2026/11/1
N2 - The convective heat transfer coefficient is a critical factor influencing the thermal comfort of walking humans, this study employs a human body-environment interface model based on CFD technology to investigate convective heat transfer characteristics. The model adopts a standardized human body model and simplifies human gait into periodic pendulum motion. Comparison with experimental measurements shows that the maximum relative deviation is 14%, while the average deviation is approximately 5.75%. Based on this validated numerical model, the convective heat transfer characteristics of a walking human body were systematically investigated. The results indicate that walking speed is the dominant influencing factor. When U increases from 0.5 m/s to 1.3 m/s, the overall hc increases by approximately 70–90%. In contrast, Ta shows a limited influence on hc. The effects of background wind speed and direction exhibit pronounced variations among different body segments. The proximal limbs and trunk are more sensitive to changes in wind direction, whereas distal segments generally exhibit lower sensitivity, with variations typically within 0.1%–4%. At a wind direction of 180°, a slight increase in hc was observed for some distal limb segments. Moreover, limb swinging weakens the shielding effect under different wind directions, resulting in nearly symmetrical hc values between the left and right sides of the body, with a maximum difference of approximately 1.6 W/(m²·K). Based on the CFD results, a correlation for predicting the convective heat transfer coefficient was developed, incorporating U, V, and θ as influencing parameters.
AB - The convective heat transfer coefficient is a critical factor influencing the thermal comfort of walking humans, this study employs a human body-environment interface model based on CFD technology to investigate convective heat transfer characteristics. The model adopts a standardized human body model and simplifies human gait into periodic pendulum motion. Comparison with experimental measurements shows that the maximum relative deviation is 14%, while the average deviation is approximately 5.75%. Based on this validated numerical model, the convective heat transfer characteristics of a walking human body were systematically investigated. The results indicate that walking speed is the dominant influencing factor. When U increases from 0.5 m/s to 1.3 m/s, the overall hc increases by approximately 70–90%. In contrast, Ta shows a limited influence on hc. The effects of background wind speed and direction exhibit pronounced variations among different body segments. The proximal limbs and trunk are more sensitive to changes in wind direction, whereas distal segments generally exhibit lower sensitivity, with variations typically within 0.1%–4%. At a wind direction of 180°, a slight increase in hc was observed for some distal limb segments. Moreover, limb swinging weakens the shielding effect under different wind directions, resulting in nearly symmetrical hc values between the left and right sides of the body, with a maximum difference of approximately 1.6 W/(m²·K). Based on the CFD results, a correlation for predicting the convective heat transfer coefficient was developed, incorporating U, V, and θ as influencing parameters.
KW - Convective heat transfer coefficient
KW - Numerical simulation
KW - Walking human model
KW - Wind direction
UR - https://www.scopus.com/pages/publications/105049155791
U2 - 10.1016/j.buildenv.2026.115191
DO - 10.1016/j.buildenv.2026.115191
M3 - 文章
AN - SCOPUS:105049155791
SN - 0360-1323
VL - 305
JO - Building and Environment
JF - Building and Environment
M1 - 115191
ER -