跳到主要导航 跳到搜索 跳到主要内容

Nonlinear finite element analysis of hip prosthesis micromotion in one gait cycle

科研成果: 期刊稿件文章同行评审

3 引用 (Scopus)

摘要

The purpose of this study is to explore the micromotion characteristics of prosthesis in gait cycle under physiological load. An anatomical CAD model of total femur was generated from CT image. The prosthesis was virtually implanted into the femur model with surgically position to form a nonlinear FEA contact model. Gait cycle was divided into 8 gait event as load step. The FEA analysis shows the micromotions of prosthesis are two kinds of rotation around the frontal axis and the sagittal axis respectively, the magnitude of the bone-implant relative micromotion range in 25 μm in one gait cycle. The micromotion is the main cause which will lead to long-term aseptic loosening of prosthesis.

源语言英语
页(从-至)607-611
页数5
期刊Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University
42
4
出版状态已出版 - 4月 2008