摘要
The cross-coupling effect is the most common phenomenon in the electric machinery operation. It has the influence on the machine efficiency and control scheme. However, the cross-coupling effect is ignored in the existing virtual signal injection (VSI) maximum torque per ampere (MTPA) control. In this article, the online searching MTPA control based on the VSI scheme for integrated starter/generator system considering the cross-coupling effect is proposed. For obtaining the accurate torque gradient with respect to the torque angle online, the torque equations in the existing VSI schemes are extended by the cross-coupling effect and the influence of the iron loss and temperature rise is studied. In this article, the partial parameters method is proposed. A prototype is set up, and the experiments are carried out to verify the effectiveness of the proposed control scheme.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 6115-6124 |
| 页数 | 10 |
| 期刊 | IEEE Transactions on Power Electronics |
| 卷 | 39 |
| 期 | 5 |
| DOI | |
| 出版状态 | 已出版 - 1 5月 2024 |