TY - JOUR
T1 - Instantaneous interface freezing induced abnormal icing dynamics during droplet impact icing
AU - Jin, Puhang
AU - Chen, Yuqiao
AU - Sun, Jiale
AU - Tan, Zhiming
AU - Zhao, Wanqing
AU - Xie, Gongnan
N1 - Publisher Copyright:
© 2025 Elsevier Ltd.
PY - 2026/1/30
Y1 - 2026/1/30
N2 - In polar regions and extreme low temperature conditions, the droplet impact icing dynamics and freezing behavior are changed by the fast freezing at the interface and heat transfer between the droplet and the substrate. In this study, the droplet impact icing hydrodynamics on substrate from −29 ℃ to −64 ℃ are characterized and studied. The actual maximum spreading diameter is redefined based on the elaborated observation and the spreading area is obtained to reflect the more real interfacial hydrodynamics. The maximum spreading diameter generally decreases with the increase in substrate supercooling. However, the spreading diameter will not decrease monotonously and even increases with further increase in substrate supercooling when substrate is cold enough. The main reason can be attributed to the existing compressed air and fast interfacial freezing, characterized by the splashing of frost at the interface, which may serve as a lubrication layer with positive effect on the droplet spreading. Regarding the bulk freezing time, the model revised in this work can predict the cases with good thermal contact between ice lamella and substrate by incorporating the Schwartz model to calculate the interfacial temperature. The discontinuous contact induced by instantaneous interface freezing and thermal–mechanical relaxation can prolong the freezing time greatly. The present study not only characterized the abnormal icing behaviors associated with quick interfacial freezing during the spreading stage of droplet impacting freezing, but also proposed a revised model to predict the freezing time of droplet impact icing with good contact. The reported phenomena can provide more insights into the instantaneous interface freezing and inspire the anti-icing method in polar regions or deep space with extreme low temperatures.
AB - In polar regions and extreme low temperature conditions, the droplet impact icing dynamics and freezing behavior are changed by the fast freezing at the interface and heat transfer between the droplet and the substrate. In this study, the droplet impact icing hydrodynamics on substrate from −29 ℃ to −64 ℃ are characterized and studied. The actual maximum spreading diameter is redefined based on the elaborated observation and the spreading area is obtained to reflect the more real interfacial hydrodynamics. The maximum spreading diameter generally decreases with the increase in substrate supercooling. However, the spreading diameter will not decrease monotonously and even increases with further increase in substrate supercooling when substrate is cold enough. The main reason can be attributed to the existing compressed air and fast interfacial freezing, characterized by the splashing of frost at the interface, which may serve as a lubrication layer with positive effect on the droplet spreading. Regarding the bulk freezing time, the model revised in this work can predict the cases with good thermal contact between ice lamella and substrate by incorporating the Schwartz model to calculate the interfacial temperature. The discontinuous contact induced by instantaneous interface freezing and thermal–mechanical relaxation can prolong the freezing time greatly. The present study not only characterized the abnormal icing behaviors associated with quick interfacial freezing during the spreading stage of droplet impacting freezing, but also proposed a revised model to predict the freezing time of droplet impact icing with good contact. The reported phenomena can provide more insights into the instantaneous interface freezing and inspire the anti-icing method in polar regions or deep space with extreme low temperatures.
KW - Droplet impact icing
KW - Freezing time
KW - Instantaneous interface freezing
KW - Large supercooling surface
KW - Maximum spreading diameter
KW - Splashing frost
UR - https://www.scopus.com/pages/publications/105022687841
U2 - 10.1016/j.applthermaleng.2025.129066
DO - 10.1016/j.applthermaleng.2025.129066
M3 - 文章
AN - SCOPUS:105022687841
SN - 1359-4311
VL - 284
JO - Applied Thermal Engineering
JF - Applied Thermal Engineering
M1 - 129066
ER -