跳到主要导航 跳到搜索 跳到主要内容

Influence of secondary hole injection angle on enhancement of film cooling effectiveness with horn-shaped or cylindrical primary holes

  • Northwestern Polytechnical University Xian
  • University of Minnesota Twin Cities

科研成果: 期刊稿件文章同行评审

27 引用 (Scopus)

摘要

Film cooling with primary and secondary hole injection is numerically investigated. Effects of primary hole shape and secondary hole injection angle are documented. Each primary hole, either cylindrical or laterally diffused, has two secondary, cylindrical holes located symmetrically about it. Adding secondary holes improves cooling performance. Five cases of different secondary hole injection configuration are analyzed. With a cylindrical primary hole, increasing secondary hole inclination angle provides better cooling; outwardly inclining the secondary holes shows continued improvement. With horn-shaped primary holes, smaller secondary hole inclination angles provide higher cooling at lower blowing ratios; larger secondary hole inclination angles provide higher cooling at higher blowing ratios, and compound-angle secondary hole injection shows no improvement over parallel hole injection.

源语言英语
页(从-至)1207-1227
页数21
期刊Numerical Heat Transfer; Part A: Applications
74
5
DOI
出版状态已出版 - 2 9月 2018

指纹

探究 'Influence of secondary hole injection angle on enhancement of film cooling effectiveness with horn-shaped or cylindrical primary holes' 的科研主题。它们共同构成独一无二的指纹。

引用此