N2 - To mitigate the flow-induced stress on pipe fittings that causes fatigue failure in convective heat exchangers, grooves structure are often incorporated into the surface geometry to reduce hydrodynamic forces and extend service life. To further investigate the effects of various groove structures on the hydrodynamic and heat transfer of pipe fittings, this study employs numerical simulations on fixed cylinders with different groove shapes and groove cover angles at Reynolds number of 100. The research mainly focuses on the flow and heat transfer characteristics around the cylinder. Hydrodynamic coefficients, pressure coefficients, Nusselt numbers, and flow field characteristics of the smooth cylinder and cylinders with different grooved surfaces are comparatively analyzed in this study. The results show that both different groove shapes and groove coverage rates have a significant impact on the hydrodynamic coefficients of the cylinder. Root-mean-square lift coefficient and drag coefficient of the cylinder with triangle grooves are the smallest when the cover angle is 50°, which are approximately 13% and 3.6% lower than those of the smooth cylinder, respectively. Meanwhile, its average Nusselt number is 12.14, which is only about 2.3% lower than that of the smooth cylinder.Overall, this structure offers the most outstanding performance.
AB - To mitigate the flow-induced stress on pipe fittings that causes fatigue failure in convective heat exchangers, grooves structure are often incorporated into the surface geometry to reduce hydrodynamic forces and extend service life. To further investigate the effects of various groove structures on the hydrodynamic and heat transfer of pipe fittings, this study employs numerical simulations on fixed cylinders with different groove shapes and groove cover angles at Reynolds number of 100. The research mainly focuses on the flow and heat transfer characteristics around the cylinder. Hydrodynamic coefficients, pressure coefficients, Nusselt numbers, and flow field characteristics of the smooth cylinder and cylinders with different grooved surfaces are comparatively analyzed in this study. The results show that both different groove shapes and groove coverage rates have a significant impact on the hydrodynamic coefficients of the cylinder. Root-mean-square lift coefficient and drag coefficient of the cylinder with triangle grooves are the smallest when the cover angle is 50°, which are approximately 13% and 3.6% lower than those of the smooth cylinder, respectively. Meanwhile, its average Nusselt number is 12.14, which is only about 2.3% lower than that of the smooth cylinder.Overall, this structure offers the most outstanding performance.
KW - Flow around bluff body
KW - Groove
KW - Heat transfer
KW - Hydrodynamic coefficient
UR - https://www.scopus.com/pages/publications/105023661147
U2 - 10.1016/j.ijheatfluidflow.2025.110169
DO - 10.1016/j.ijheatfluidflow.2025.110169
M3 - 文章
AN - SCOPUS:105023661147
SN - 0142-727X
VL - 118
JO - International Journal of Heat and Fluid Flow
JF - International Journal of Heat and Fluid Flow
M1 - 110169
ER -