N2 - Purpose: Thyroid nodules are highly prevalent in the general population, yet large-scale ultrasound screening is limited by its reliance on experienced sonographers. Autonomous robotic ultrasound systems have the potential to enable standardized thyroid screening with reduced operator dependency. Methods: In this pilot prospective study, a fully autonomous robotic ultrasound system was evaluated for thyroid nodule screening in a clinical setting. Twenty-one consecutive participants underwent both autonomous robotic ultrasound and standard operator-performed ultrasound examinations in a randomized order. The primary outcome was participant-level thyroid nodule detection rate compared with operator-performed ultrasound. Secondary outcomes included feasibility, thyroid gland coverage, and participant-reported comfort. Results: Autonomous robotic ultrasound was successfully completed without human intervention in 20 of 21 participants (95.2%). Thyroid nodules were identified on operator-performed ultrasound in nine participants, of whom eight were correctly detected by the autonomous system, corresponding to a participant-level detection rate of 88.9%. Complete coverage of the left lobe, right lobe, and isthmus was achieved in 100%, 95%, and 80% of participants, respectively. Participant-reported comfort was neutral to positive, with a median Likert score of 3 (interquartile range, 3–4). Conclusion: This pilot study demonstrated the feasibility of fully autonomous robotic ultrasound for standardized thyroid nodule screening. The system achieved high completion rates and acceptable screening performance in a controlled clinical setting, supporting further validation in larger and more diverse populations.
AB - Purpose: Thyroid nodules are highly prevalent in the general population, yet large-scale ultrasound screening is limited by its reliance on experienced sonographers. Autonomous robotic ultrasound systems have the potential to enable standardized thyroid screening with reduced operator dependency. Methods: In this pilot prospective study, a fully autonomous robotic ultrasound system was evaluated for thyroid nodule screening in a clinical setting. Twenty-one consecutive participants underwent both autonomous robotic ultrasound and standard operator-performed ultrasound examinations in a randomized order. The primary outcome was participant-level thyroid nodule detection rate compared with operator-performed ultrasound. Secondary outcomes included feasibility, thyroid gland coverage, and participant-reported comfort. Results: Autonomous robotic ultrasound was successfully completed without human intervention in 20 of 21 participants (95.2%). Thyroid nodules were identified on operator-performed ultrasound in nine participants, of whom eight were correctly detected by the autonomous system, corresponding to a participant-level detection rate of 88.9%. Complete coverage of the left lobe, right lobe, and isthmus was achieved in 100%, 95%, and 80% of participants, respectively. Participant-reported comfort was neutral to positive, with a median Likert score of 3 (interquartile range, 3–4). Conclusion: This pilot study demonstrated the feasibility of fully autonomous robotic ultrasound for standardized thyroid nodule screening. The system achieved high completion rates and acceptable screening performance in a controlled clinical setting, supporting further validation in larger and more diverse populations.
KW - Autonomous robotic ultrasound
KW - Feasibility study
KW - Medical robotics
KW - Thyroid nodule screening
UR - https://www.scopus.com/pages/publications/105043706405
U2 - 10.1007/s10396-026-01667-z
DO - 10.1007/s10396-026-01667-z
M3 - 文章
AN - SCOPUS:105043706405
SN - 1346-4523
JO - Journal of Medical Ultrasonics (Singapore)
JF - Journal of Medical Ultrasonics (Singapore)
ER -