TY - JOUR
T1 - Experimental and numerical study of transpiration cooling in an octet-truss array structure
AU - Li, Yuxi
AU - Bai, Xiaohui
AU - Duan, Chengao
AU - Liu, Cunliang
N1 - Publisher Copyright:
© 2026 Elsevier Masson SAS.
PY - 2027/3
Y1 - 2027/3
N2 - To improve thermal protection under high heat flux conditions, this study investigates the flow and heat transfer characteristics of transpiration cooling structures based on octet-truss lattice (OTL) arrays through experiments and numerical simulations. Cooling performance is compared with that of square-pore structures, considering the effects of porosity, blowing ratio, mainstream Reynolds number, and inlet temperatures. Experimental results show that OTL structures achieve higher overall cooling effectiveness at the same porosity, with improvements of 8.99%–11.51% over blowing ratios of 5.12%–20.46%. This enhancement is associated with their larger internal heat transfer area and enhanced coolant–solid heat exchange, although it is accompanied by increased pressure drop. Reducing the porosity from 58.4% to 47.6% increases the cooling effectiveness of the OTL structure by 7.76% at a blowing ratio of 10.23%. Increasing the blowing ratio yields diminishing cooling benefits, whereas increasing the mainstream Reynolds number reduces cooling effectiveness, with a maximum experimental reduction of 9.55% within the tested conditions. Changes in inlet temperatures further reveal that overall cooling effectiveness and absolute wall temperature can exhibit different trends, highlighting the need to consider both quantities when assessing thermal protection. These findings provide insights into the cooling mechanisms of OTL structures and guide transpiration cooling design by considering both cooling effectiveness and flow resistance.
AB - To improve thermal protection under high heat flux conditions, this study investigates the flow and heat transfer characteristics of transpiration cooling structures based on octet-truss lattice (OTL) arrays through experiments and numerical simulations. Cooling performance is compared with that of square-pore structures, considering the effects of porosity, blowing ratio, mainstream Reynolds number, and inlet temperatures. Experimental results show that OTL structures achieve higher overall cooling effectiveness at the same porosity, with improvements of 8.99%–11.51% over blowing ratios of 5.12%–20.46%. This enhancement is associated with their larger internal heat transfer area and enhanced coolant–solid heat exchange, although it is accompanied by increased pressure drop. Reducing the porosity from 58.4% to 47.6% increases the cooling effectiveness of the OTL structure by 7.76% at a blowing ratio of 10.23%. Increasing the blowing ratio yields diminishing cooling benefits, whereas increasing the mainstream Reynolds number reduces cooling effectiveness, with a maximum experimental reduction of 9.55% within the tested conditions. Changes in inlet temperatures further reveal that overall cooling effectiveness and absolute wall temperature can exhibit different trends, highlighting the need to consider both quantities when assessing thermal protection. These findings provide insights into the cooling mechanisms of OTL structures and guide transpiration cooling design by considering both cooling effectiveness and flow resistance.
KW - Flow heat transfer coupling
KW - Lattice truss
KW - Octet-truss structure
KW - Porous medium
KW - Transpiration cooling
UR - https://www.scopus.com/pages/publications/105052703691
U2 - 10.1016/j.ijthermalsci.2026.111395
DO - 10.1016/j.ijthermalsci.2026.111395
M3 - 文章
AN - SCOPUS:105052703691
SN - 1290-0729
VL - 233
JO - International Journal of Thermal Sciences
JF - International Journal of Thermal Sciences
M1 - 111395
ER -