跳到主要导航 跳到搜索 跳到主要内容

Enhanced Au/Semi-Insulating Single-Crystal CdTe Schottky-Type Radiation Detectors Based on van der Waals Contacts

  • Zhengyi Sun
  • , Yi Liu
  • , Dan Zheng
  • , Hongguang Liu
  • , Jian Li
  • , Ziang Yin
  • , Baoqiang Zhang
  • , Suyu Chen
  • , Ning Han
  • , Qinghua Zhao
  • , Volodymyr Gnatyuk
  • , Tao Wang
  • Northwestern Polytechnical University Xian
  • Imdetek Co., Ltd
  • Chongqing Jianan Instruments Company Ltd.
  • Advafab Oy

科研成果: 期刊稿件 › 文章 › 同行评审

2 引用 (Scopus)

摘要

Cadmium telluride (CdTe) remains a leading semiconductor material for room-temperature high-energy radiation detection. Despite advances in single-crystal growth that have pushed CdTe’s resistivity near its intrinsic limit, detectors still suffer from current noise under high bias. Schottky contacts or p-n junctions are commonly used to suppress leakage current while preserving charge transport, but their performance in bulk CdTe is hindered by strong Fermi-level pinning. We demonstrate a van der Waals (vdW) contact integration approach that mitigates Fermi-level pinning and significantly reduces dark current. This study presents a novel approach to enhancing Schottky-type X/γ-ray detectors based on semi-insulating CdTe crystals using vdW contacts. Gold (Au) electrodes were mechanically transferred onto CdTe surfaces to minimize surface damage and mitigate Fermi-level pinning. Cross-sectional transmission electron microscopy (TEM) confirms the absence of atomic intermixing at the Au–CdTe interface, validating the noninvasive nature of the vdW contact. In contrast, Au contacts deposited by evaporation show residual contamination, as revealed by X-ray photoelectron spectroscopy (XPS), along with increased defect states confirmed by low-temperature photoluminescence (PL). For mechanically transferred contacts vdW, both XPS and PL spectra closely match those of pristine CdTe, indicating minimal surface degradation. This improved interface quality correlates with an increase in the Schottky barrier height (SBH) from 0.78 to 0.82 eV. As a result, Au/CdTe/Au detectors with vdW contacts exhibit reduced dark current and improved energy resolution (from 14.4% to 11.8%) for 59.5-keV γ-ray from a 241Am isotope. These findings demonstrate the potential of vdW contact engineering to significantly improve the performance of CdTe-based radiation detectors.

源语言英语
页(从-至)3792-3800
页数9
期刊IEEE Transactions on Nuclear Science
卷72
期12
DOI
出版状态已出版 - 2025

学术指纹

探究 'Enhanced Au/Semi-Insulating Single-Crystal CdTe Schottky-Type Radiation Detectors Based on van der Waals Contacts' 的科研主题。它们共同构成独一无二的学术指纹。

引用此