跳到主要导航 跳到搜索 跳到主要内容

Durable and Robust Antibacterial Polypropylene Hernia Mesh for Abdominal Wall Defect Repair

  • Rui Ding
  • , Luofeng Yu
  • , Pandi Peng
  • , Jiajun Zhang
  • , Haoqi Xu
  • , Haoyu Li
  • , Hanxue Wu
  • , Likun Yan
  • , Peng Li
  • Northwestern Polytechnical University Xian
  • Shaanxi Provincial People’s Hospital
  • Henan University

科研成果: 期刊稿件 › 文章 › 同行评审

11 引用 (Scopus)

摘要

Polypropylene (PP) mesh is commonly used in repairing abdominal wall hernia (AWH). However, the use of synthetic prosthesis comes with the risk of developing a prosthetic infection, resulting in delayed healing, secondary surgery, and potentially increased mortality. To address these issues, a facile surface functionalization strategy for PP mesh based on phytic acid (PA) and polyhexamethylene guanidine (PHMG) was constructed through a one-step co-deposition process, referred to as the PA/PHMG coating. The development of PA/PHMG coating is mainly attributed to the surface affinity of PA and the electrostatic interactions between PA and PHMG. The PA/PHMG coating could be completed within 4 h under mild conditions. The prepared PA/PHMG coatings on PP mesh surfaces exhibited desirable biocompatibility toward mammalian cells and excellent antibacterial properties against the notorious “superbug” methicillin-resistant Staphylococcus aureus (MRSA) and tetracycline-resistant Escherichia coli (TRE). The PA/PHMG-coated PP meshes showed killing ratios of over 99% against MRSA in an infected abdominal wall hernia repair model. Furthermore, histological and immunohistochemical analysis revealed a significantly attenuated degree of neutrophil infiltration in the PA/PHMG coating group, attributed to the decreased bacterial numbers alleviating the inflammatory response at the implant sites. Meanwhile, the pristine PP and PA/PHMG-coated meshes showed effective tissue repair, with the PA/PHMG coating group exhibiting enhanced angiogenesis compared with pristine PP meshes, suggesting superior tissue restoration. Additionally, PP meshes with the highest PHMG weight ratio (PA/PHMG(3)) exhibited excellent long-term robustness under phosphate-buffered saline (PBS) immersion with a killing ratio against MRSA still exceeding 95% after 60 days of PBS immersion. The present work provides a facile and promising approach for developing antibacterial implants.

源语言英语
页(从-至)25686-25697
页数12
期刊ACS Applied Materials and Interfaces
卷16
期20
DOI
出版状态已出版 - 22 5月 2024

学术指纹

探究 'Durable and Robust Antibacterial Polypropylene Hernia Mesh for Abdominal Wall Defect Repair' 的科研主题。它们共同构成独一无二的学术指纹。

引用此