跳到主要导航 跳到搜索 跳到主要内容

Design and fabrication of a flat plate radioisotope micro battery for MEMS

  • Northwestern Polytechnical University Xian

科研成果: 期刊稿件 › 文章 › 同行评审

摘要

Channels array and inverted pyramid array Radioisotope Micro Battery suffer from difficulty to fabricating and non-uniform of the radioactive film. In order to solve these defects, a novel simple flat plate energy conversion device is designed. The metallic section is introduced to enhance the reliability of the radioactive film with the silicon base. In ourexperimentsof63Ni electric plating, a group of anticipant data of short-circuit current and open-circuit voltage were obtained. The results shows that compared to the conventional devices, the flat plat energy conversion device can offer amore reliable power output.

源语言英语
页(从-至)319-322
页数4
期刊Gongneng Cailiao yu Qijian Xuebao/Journal of Functional Materials and Devices
卷14
期2
出版状态已出版 - 4月 2008

学术指纹

探究 'Design and fabrication of a flat plate radioisotope micro battery for MEMS' 的科研主题。它们共同构成独一无二的学术指纹。

引用此