摘要
The thermal properties for the multi-re-entrant honeycomb are investigated, where the hexagon and re-entrant topologies are applied for comparison. A compact model was adopted for the local heat transfer rate and pressure drop estimations while the total heat transfer rate was analyzed using the transfer matrix method. A thermal performance index was specified to characterize a good heat exchange medium that can transfer more heat at the expense of lower pressure loss. Numerical results reveal better thermal performances of multi-re-entrant honeycombs over hexagon and re-entrant topologies, attributed to the presence of added base walls. Auxetic effect introduced in multi-re-entrant honeycomb generally provides enhanced out-of-plane thermal conductivity and increased total heat transfer efficiency due to higher surface area density.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 1765-1782 |
| 页数 | 18 |
| 期刊 | Heat and Mass Transfer/Waerme- und Stoffuebertragung |
| 卷 | 50 |
| 期 | 12 |
| DOI | |
| 出版状态 | 已出版 - 12月 2014 |