N2 - By means of the weighted residual, the natural frequencies of pipe conveying non-uniform axial fluid are calculated. In the process of analyzing, the trial function is also constituted via the order Galerkin truncation: After establishing the performance function of the resonance reliability of pipe conveying fluid, the resonance reliability sensitivity is deduced from the weighted nonlinear response surface method and Monte-Carlo reliability sensitivity estimation. The example results show that the proposed method is reasonable, high efficient and high precise. The research in this paper is valuable for anti-resonance design and reliability sensitivity estimation of pipe conveying non-uniform axial fluid.
AB - By means of the weighted residual, the natural frequencies of pipe conveying non-uniform axial fluid are calculated. In the process of analyzing, the trial function is also constituted via the order Galerkin truncation: After establishing the performance function of the resonance reliability of pipe conveying fluid, the resonance reliability sensitivity is deduced from the weighted nonlinear response surface method and Monte-Carlo reliability sensitivity estimation. The example results show that the proposed method is reasonable, high efficient and high precise. The research in this paper is valuable for anti-resonance design and reliability sensitivity estimation of pipe conveying non-uniform axial fluid.
KW - Non-uniform axial fluid
KW - Pipe conveying fluid
KW - Resonance reliability sensitivity
KW - Weighted nonlinear response surface method
UR - https://www.scopus.com/pages/publications/84870266833
M3 - 文章
AN - SCOPUS:84870266833
SN - 0254-7805
VL - 33
SP - 480
EP - 486
JO - Guti Lixue Xuebao/Acta Mechanica Solida Sinica
JF - Guti Lixue Xuebao/Acta Mechanica Solida Sinica
IS - 5
ER -