跳到主要导航 跳到搜索 跳到主要内容

Accuracy synthesis of Stewart platform used in testing system for spacecraft docking mechanism

  • School of Mechatronics Engineering, Harbin Institute of Technology

科研成果: 书/报告/会议事项章节会议稿件同行评审

7 引用 (Scopus)

摘要

Stewart platform used in testing system for two spacecraft's motion docking mechanism requires high accuracy to achieve better simulation result. In this paper, an accuracy synthesis of the Stewart platform used in a testing system for spacecraft docking mechanism is presented. The method is based on the error model formed through differentiation of the kinematics equations of the platform and the investigation of sensitivity analysis in its workspace. The accuracy synthesis is implemented to allocate error parameters. Experimental results show errors of the Stewart platform are less than 1mm in whole 2000mm scales, and verifies the effectiveness of our method.

源语言英语
主期刊名2009 International Conference on Measuring Technology and Mechatronics Automation, ICMTMA 2009
7-10
页数4
DOI
出版状态已出版 - 2009
已对外发布
活动2009 International Conference on Measuring Technology and Mechatronics Automation, ICMTMA 2009 - Zhangjiajie, Hunan, 中国
期限: 11 4月 200912 4月 2009

出版系列

姓名2009 International Conference on Measuring Technology and Mechatronics Automation, ICMTMA 2009
3

会议

会议2009 International Conference on Measuring Technology and Mechatronics Automation, ICMTMA 2009
国家/地区中国
Zhangjiajie, Hunan
时期11/04/0912/04/09

指纹

探究 'Accuracy synthesis of Stewart platform used in testing system for spacecraft docking mechanism' 的科研主题。它们共同构成独一无二的指纹。

引用此