摘要
To prevent the carbon/carbon (C/C) composites from ablation, a new type of ablation protective coating was prepared on the surface of the C/C composites by a step pack cementation technique. X-ray diffraction (XRD) and scanning electron microscopy (SEM) analysis show, the coatings obtained by pack cementation were silicon carbide/tantalum silicide (SiC-TaSi2). The ablation behavior of the coated samples were evaluated by the oxyacetylene flame. The results show that, the SiC-TaSi2 coating can improve the anti-ablative properties of C/C composites effectively. The mass ablation rate for the coated C/C composites was only 7.7 × 10-4 g/s, which was lower by 79% than that of the C/C composites after ablation for 30 s.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 487-491 |
| 页数 | 5 |
| 期刊 | Surface Review and Letters |
| 卷 | 17 |
| 期 | 5-6 |
| DOI | |
| 出版状态 | 已出版 - 10月 2010 |