A surface-modified cyclic olefin copolymer pillar array column for on-chip liquid chromatography to detect glycated hemoglobin levels

  • Hantian Zhang
  • , Ruirong Zhang
  • , Dezhao Jiao
  • , Bo Wang
  • , Haitao Zhao
  • , Xiaoguang Fan
  • , Honglong Chang
  • Northwestern Polytechnical University Xian

科研成果: 期刊稿件文章同行评审

1 引用 (Scopus)

摘要

Liquid chromatography (LC) for glycated hemoglobin (HbA1c) testing is an important method for diagnosing and monitoring diabetes mellitus (DM). To remain competitive with current point-of-care testing (POCT) devices, several miniaturized LC systems for HbA1c testing have been developed. Currently, the chromatographic columns in miniaturized LC systems for HbA1c separation are mainly packed columns, which have high back pressure. This puts high demand on column fabrication and restricts the integration of components in miniaturized LC systems. Therefore, it is important to consider alternatives to the current packed columns that offer lower back pressure. Here, we present a cyclic olefin copolymer (COC) pillar array column with reduced back pressure in the microchip for miniaturized LC to detect HbA1c levels. The microchip incorporating the pillar array column is produced through hot embossing, surface modification and thermal sealing. Notably, the surface of the COC pillar array column is modified with sulfonic acid ([sbnd]SO3H) groups via photochemical grafting, enabling the chromatographic separation of HbA1c. This microchip, used in conjunction with commercial LC components, performs analysis of blood calibrator samples with four different HbA1c levels. Under the optimized separation conditions, HbA1c levels are measurable within a short analysis time of 3 min, with a coefficient of variation under 4.2 % and a correlation coefficient of 0.9856. The theoretical plate numbers for HbA1c and HbA0 eluted from samples were calculated at 5450 and 2030 plates/m, respectively. In comparison with existing microchips for HbA1c analysis, the developed microchip offers smaller size and lower back pressure, greatly facilitating the development of miniaturized LC systems. Additionally, the developed pillar array column is anticipated to be applicable for separating other biological marker proteins.

源语言英语
文章编号114899
期刊Microchemical Journal
217
DOI
出版状态已出版 - 10月 2025

联合国可持续发展目标

此成果有助于实现下列可持续发展目标:

  1. 可持续发展目标 3 - 良好健康与福祉
    可持续发展目标 3 良好健康与福祉

学术指纹

探究 'A surface-modified cyclic olefin copolymer pillar array column for on-chip liquid chromatography to detect glycated hemoglobin levels' 的科研主题。它们共同构成独一无二的学术指纹。

引用此