摘要
The development of the dc microgrid system on-board has promoted the development of the dc circuit breaker, but short circuit fault may cause serious damage to the system. Many problems exist in the traditional dc circuit breaker such as long periods of fault interruption, complex circuit structure, existing arc, low reliability, and low anti-interference. Aiming to solve these problems, a novel solid-state dc circuit breaker is proposed in this paper. First, this paper analyzes the working principle and process of the circuit in detail according to the results of the simulation based on Saber. Second, this paper gives the criteria on how to choose the parameters of the components correctly in the circuit. The concept of the maximum fault resistance according to the minimum fault current is also introduced. Moreover, this paper analyzes the influence of the minimum fault ramp rate on the circuit performance. Finally, experimental results verify that the performance of this novel solid-state circuit breaker agree with the theoretical analysis.
| 源语言 | 英语 |
|---|---|
| 文章编号 | 8415755 |
| 页(从-至) | 5715-5723 |
| 页数 | 9 |
| 期刊 | IEEE Transactions on Industrial Electronics |
| 卷 | 66 |
| 期 | 7 |
| DOI | |
| 出版状态 | 已出版 - 7月 2019 |
学术指纹
探究 'A Novel Solid-State Circuit Breaker for On-Board DC Microgrid System' 的科研主题。它们共同构成独一无二的学术指纹。引用此
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver