TY - JOUR
T1 - A large inertia load PMSM power down-rejoining on optimizing control system
AU - Gao, Ya
AU - Liu, Weiguo
AU - Luo, Guangzhao
PY - 2014/5
Y1 - 2014/5
N2 - Aiming to the current and torque impact of large inertia load permanent magnet synchronous motor (PMSM) when power down-rejoining on with a high speed, a closed-loop transient optimizing control system is investigated in this paper. Firstly, the concept of equivalent damping windings is introduced, and the accuracy of the non-salient pole PMSM mathematical model based on transient analyzing is improved. Based on the new mathematical model of motor, the origin of transient impact when rejoining power-on and the affect of given speed are analyzed. According to the results of the analysis, a certain requirement for given speed of the closed-loop control system is proposed. Simultaneously, a voltage simulation controller and optimizing controller are designed. Finally, the experiments and simulations verify the validity of the analysis and the positive role of reducing the impact for designed optimizing control system.
AB - Aiming to the current and torque impact of large inertia load permanent magnet synchronous motor (PMSM) when power down-rejoining on with a high speed, a closed-loop transient optimizing control system is investigated in this paper. Firstly, the concept of equivalent damping windings is introduced, and the accuracy of the non-salient pole PMSM mathematical model based on transient analyzing is improved. Based on the new mathematical model of motor, the origin of transient impact when rejoining power-on and the affect of given speed are analyzed. According to the results of the analysis, a certain requirement for given speed of the closed-loop control system is proposed. Simultaneously, a voltage simulation controller and optimizing controller are designed. Finally, the experiments and simulations verify the validity of the analysis and the positive role of reducing the impact for designed optimizing control system.
KW - Error compensating
KW - Optimizing control
KW - Permanent magnet synchronous motor
KW - Power down-rejoining on
KW - Voltage simulation control
UR - https://www.scopus.com/pages/publications/84901641785
M3 - 文章
AN - SCOPUS:84901641785
SN - 1000-6753
VL - 29
SP - 62
EP - 69
JO - Diangong Jishu Xuebao/Transactions of China Electrotechnical Society
JF - Diangong Jishu Xuebao/Transactions of China Electrotechnical Society
IS - 5
ER -