摘要
To verify the feasibility of the jet impinging-regenerative channel composite cooling technology,the steady-state liquid crystal technology was used to measure the Nusselt number of ambient air under the initial crossflow cooling,jet impinging cooling,and jet impinging-initial crossflow composite cooling,respectively. The experimental results show that the heat transfer effect of jet-impinging cooling and jet-impinging-initial crossflow composite cooling was improved by 207.55%—370.24% and 428.35%—545.35%, respectively, compared with the situation of initial crossflow cooling, and the heat transfer performance of jet impinging-initial crossflow composite cooling was better than that of jet impinging cooling under all flow conditions. The optimal relationship among the number of jet holes, jet flow rate,and initial crossflow rate can maximize the heat transfer performance: Jet impinging can greatly improve the heat transfer performance of the target surface, but the improvement amplitude decreases with the increase of flow rate,and the increase of jet holes can improve the uniformity of temperature distribution on the target surface. When the jet touches the target surface and the momentum is suitable, the initial crossflow can further increase the Nusselt number effectively. When the flow rate is too small and the jet cannot reach the target surface, the combined disturbance of the initial crossflow and jet impinging can also improve the heat transfer performance.
| 投稿的翻译标题 | Experimental study on the composite cooling performance of jet impinging-regenerative channel |
|---|---|
| 源语言 | 繁体中文 |
| 期刊论文编号 | 20240205 |
| 期刊 | Hangkong Dongli Xuebao/Journal of Aerospace Power |
| 卷 | 41 |
| 期 | 2 |
| DOI | |
| 出版状态 | 已出版 - 2月 2026 |
关键词
- initial crossflow
- jet impinging
- Nusselt number
- regenerative cooling
- scramjet engine
学术指纹
探究 '射流冲击-再生通道复合冷却性能的实验研究' 的科研主题。它们共同构成独一无二的学术指纹。引用此
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver