Valve fault diagnosis of a reciprocating compressor based on hybrid method

  • Si Yang Zhang
  • , Min Qiang Xu
  • , Yong Bo Li
  • , Hai Yang Zhao
  • , Ri Xin Wang
  • Harbin Institute of Technology
  • PetroChina Harbin Petrochemical Company

Research output: Contribution to journal › Article › peer-review

4 Scopus citations

Abstract

Due to strong nonlinear and non-stationary characteristics of a reciprocating compressor's valve vibration signals, the cubic spline interpolation EEMD (S-EEMD) method well utilized still has shortages of mode mixing and envelop inaccurate. Aiming at the above mentioned problems, the combined analysis method of EEMD based on the quartic Hermite interpolation (QH-EEMD) and the power spectral entropy (PSE) was proposed. The original signals were decomposed into a set of IMF components using the quartic Hermite method with advantages of shape-preserving and adjustability and the EEMD method promoting signals' continuity in different decomposing scale to improve the approximation accuracy of the interpolation curve and to decrease mode mixing. The advantages of the QH-EEMD with PSE (QH-EEMD with PSE) analysis method were verified comparing with those of the S-EEMD-PSE (S-EEMD with PSE) method and the QH-EEMD-SE (QH-EEMD with sample entropy) method. Taking common faults of a reciprocating compressor as the study objects, feature vectors of faults were extracted based on the QH-EEMD-PSE method and the faults were diagnosed accurately.

Original languageEnglish
Pages (from-to)167-173
Number of pages7
JournalZhendong yu Chongji/Journal of Vibration and Shock
Volume35
Issue number11
DOIs
StatePublished - 15 Jun 2016
Externally publishedYes

Keywords

  • EEMD
  • Fault diagnosis
  • Power spectral entropy (PSE)
  • Reciprocating compressor