TY - JOUR
T1 - Uniform and Complete Irreversible Electroporation on Gastric Mucosa Enabled by Sintered Silver Hydrogel
AU - Li, Zhuoqun
AU - Lei, Shenshen
AU - Li, Quanpeng
AU - Lin, Fulai
AU - Lv, Jian
AU - Gong, Yonghui
AU - Ping, Zhuomin
AU - Wang, Chengjiang
AU - Cheng, Yuchen
AU - Liu, Wenna
AU - Zhong, Dingming
AU - Li, Yutang
AU - Wang, Yuhao
AU - Ma, Feng
AU - Shi, Aihua
AU - Chen, Xiaoliang
AU - Kong, Chuncai
AU - Sun, Bai
AU - Luo, Sihai
AU - Tao, Jie
AU - Wu, Rongqian
AU - Sun, Hao
AU - Wu, Zheng
AU - He, Shuixiang
AU - Ji, Bowen
AU - Yu, Xinge
AU - Shao, Jinyou
AU - Ren, Fenggang
AU - Lyu, Yi
N1 - Publisher Copyright:
Copyright © 2026 Zhuoqun Li et al.
PY - 2026/1
Y1 - 2026/1
N2 - Irreversible electroporation is a promising nonthermal ablation for gastric mucosa, but nonconformal contact between the electrode and the rough surface of the gastric mucosa causes an inhomogeneous distribution of the high-voltage electric field. Here, we enhanced gap filling and substantially reduced distortion of the delivered high-voltage electric field by fabricating a soft, highly conductive sintered silver hydrogel as the bioelectronic tissue interface, thereby achieving uniform and complete irreversible electroporation. The sintering reaction was initiated by Cl− and H+, which can work synergistically to partially eliminate the insulating surfactant on silver flakes, facilitating a sintering reaction through the dynamic redeposition of silver nanoparticles on silver flakes. Via a room-temperature sintering process, the conductivity of the hydrogel was promoted from below 1 to >104 S/m at a low silver flake loading (4 vol%), and the mechanical property was still kept at a low Young’s modulus (91 kPa), even after swelling from digestive juices. In vitro experiments demonstrated that ablation uniformity improved by up to 86%, with the ablation area increasing by 30% to 52% and a maximum depth of 5.39 mm. Preclinical validation using porcine models demonstrated uniform, complete gastric mucosal ablation, reaching a depth of 2.50 mm, extending through the muscularis mucosae and leaving no residual cells.This sintered silver hydrogel-enhanced irreversible electroporation addresses key challenges and reinforces its potential as a reliable, advanced treatment for gastrointestinal lesions.
AB - Irreversible electroporation is a promising nonthermal ablation for gastric mucosa, but nonconformal contact between the electrode and the rough surface of the gastric mucosa causes an inhomogeneous distribution of the high-voltage electric field. Here, we enhanced gap filling and substantially reduced distortion of the delivered high-voltage electric field by fabricating a soft, highly conductive sintered silver hydrogel as the bioelectronic tissue interface, thereby achieving uniform and complete irreversible electroporation. The sintering reaction was initiated by Cl− and H+, which can work synergistically to partially eliminate the insulating surfactant on silver flakes, facilitating a sintering reaction through the dynamic redeposition of silver nanoparticles on silver flakes. Via a room-temperature sintering process, the conductivity of the hydrogel was promoted from below 1 to >104 S/m at a low silver flake loading (4 vol%), and the mechanical property was still kept at a low Young’s modulus (91 kPa), even after swelling from digestive juices. In vitro experiments demonstrated that ablation uniformity improved by up to 86%, with the ablation area increasing by 30% to 52% and a maximum depth of 5.39 mm. Preclinical validation using porcine models demonstrated uniform, complete gastric mucosal ablation, reaching a depth of 2.50 mm, extending through the muscularis mucosae and leaving no residual cells.This sintered silver hydrogel-enhanced irreversible electroporation addresses key challenges and reinforces its potential as a reliable, advanced treatment for gastrointestinal lesions.
UR - https://www.scopus.com/pages/publications/105053595070
U2 - 10.34133/cbsystems.0697
DO - 10.34133/cbsystems.0697
M3 - 文章
AN - SCOPUS:105053595070
SN - 2097-1087
VL - 7
JO - Cyborg and Bionic Systems
JF - Cyborg and Bionic Systems
M1 - 0697
ER -