TY - GEN
T1 - Study of the Detection Method of Series AC Arc Faults Based on High-frequency Zero-sequence Current Coupling Signal
AU - He, Zhipeng
AU - Zhang, Yezhen
AU - Li, Weilin
AU - Zhao, Hu
AU - Li, Bingqiang
N1 - Publisher Copyright:
© 2023 IEEE.
PY - 2023
Y1 - 2023
N2 - Arc fault is one of the main causes of electrical fire hazards. Most research is mainly based on current signals to detect arc faults. However, load type and other factors easily affect the current signal, which easily causes missed judgment and misjudgment of switches. To solve this issue, this paper proposes a detection method based on the high-frequency zero-sequence current coupling signal for low-voltage series AC arc faults. First, an experimental platform was built for low-voltage series AC arc fault according to the IEC 62606 standard, and the high-frequency zero-sequence current coupling signal of ten typical loads under different line conditions was collected. Then, the characteristics of zero-sequence current under different loads and line conditions were analyzed, and the arc fault detection algorithm was developed according to the different characteristics of the line's normal and arc-fault states. Finally, the effectiveness, stability, and applicability of the arc fault detection method were verified by various experimental conditions with a prototype. The result shows that the detection accuracy of the presented method is about 98%, which has a certain guiding significance for the development of arc fault detection devices.
AB - Arc fault is one of the main causes of electrical fire hazards. Most research is mainly based on current signals to detect arc faults. However, load type and other factors easily affect the current signal, which easily causes missed judgment and misjudgment of switches. To solve this issue, this paper proposes a detection method based on the high-frequency zero-sequence current coupling signal for low-voltage series AC arc faults. First, an experimental platform was built for low-voltage series AC arc fault according to the IEC 62606 standard, and the high-frequency zero-sequence current coupling signal of ten typical loads under different line conditions was collected. Then, the characteristics of zero-sequence current under different loads and line conditions were analyzed, and the arc fault detection algorithm was developed according to the different characteristics of the line's normal and arc-fault states. Finally, the effectiveness, stability, and applicability of the arc fault detection method were verified by various experimental conditions with a prototype. The result shows that the detection accuracy of the presented method is about 98%, which has a certain guiding significance for the development of arc fault detection devices.
KW - Arc fault
KW - characteristics
KW - detection method
KW - high-frequency zero-sequence current
UR - https://www.scopus.com/pages/publications/85182325560
U2 - 10.1109/HOLM56075.2023.10352218
DO - 10.1109/HOLM56075.2023.10352218
M3 - 会议稿件
AN - SCOPUS:85182325560
T3 - Electrical Contacts, Proceedings of the Annual Holm Conference on Electrical Contacts
BT - Electrical Contacts 2023 - Proceedings of the 68th IEEE Holm Conference on Electrical Contacts, HOLM 2023
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 68th IEEE Holm Conference on Electrical Contacts, HOLM 2023
Y2 - 4 October 2023 through 11 October 2023
ER -