As UUVs evolve toward high-performance capabilities, such as high speeds and long endurance, the thermal management requirements of their battery systems are increasing. To address this issue, this paper designed and investigated a novel closed-loop serpentine liquid-cooling system. Based on this, a high-fidelity, three-dimensional, full-scale thermal-flow coupled numerical model was developed to investigate the effects of coolant flow rate, cooling plate length, flow channel length and channel structure on the overall thermal management performance and energy consumption characteristics of UUV battery pack. Under extreme 5C discharge conditions, the system reduced the battery temperature by 39.72 K compared with air cooling, corresponding to a suppression rate of 76.05%. Further results indicated that with increasing Qv, both T_max and ΔT decreased, while the reduction rate gradually diminished, and a flow rate of 0.5 L/min was recommended. The effects of Lh and Lw on the thermal behavior of the system followed a similar trend to that of Qv. Among them, Lh = 55 mm was sufficient to satisfy the thermal requirement, whereas Lw had a limited impact on temperature control but contributed to reduced energy consumption and improved cooling efficiency. Furthermore, both diverging and converging channels reduced the battery pack temperature. However, their effects on temperature uniformity exhibited opposite trends. Under identical energy consumption conditions, the converging channel demonstrated a higher heat dissipation capability. In addition, compared with the uniform channel, channels with depressions or protrusions not only failed to enhance thermal performance but also resulted in higher energy consumption.

Original languageEnglish
Article number112524
JournalInternational Communications in Heat and Mass Transfer
Volume180
Issue numberP1
DOIs
StatePublished - Nov 2026

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

Keywords

  • Battery thermal management system
  • Coolant circulation
  • High-rate discharge
  • Liquid cooling
  • Serpentine channel
  • UUV battery pack

Fingerprint

Dive into the research topics of 'Research on UUV battery pack thermal management using a novel closed-loop serpentine liquid cooling design'. Together they form a unique fingerprint.

Cite this