Skip to main navigation Skip to search Skip to main content

Precisely Structured Nitric-Oxide-Releasing Copolymer Brush Defeats Broad-Spectrum Catheter-Associated Biofilm Infections in Vivo

  • Zheng Hou
  • , Yang Wu
  • , Chen Xu
  • , Sheethal Reghu
  • , Zifang Shang
  • , Jingjie Chen
  • , Dicky Pranantyo
  • , Kalisvar Marimuth
  • , Partha Pratim De
  • , Oon Tek Ng
  • , Kevin Pethe
  • , En Tang Kang
  • , Peng Li
  • , Mary B. Chan-Park
  • Nanyang Technological University
  • Northwestern Polytechnical University Xian
  • National University of Singapore
  • Tan Tock Seng Hospital
  • National Centre for Infectious Diseases

Research output: Contribution to journalArticlepeer-review

60 Scopus citations

Abstract

Gram-negative bacteria cannot be easily eradicated by antibiotics and are a major source of recalcitrant infections of indwelling medical devices. Among various device-associated infections, intravascular catheter infection is a leading cause of mortality. Prior approaches to surface modification, such as antibiotics impregnation, hydrophilization, unstructured NO-releasing, etc., have failed to achieve adequate infection-resistant coatings. We report a precision-structured diblock copolymer brush (H(N)-b-S) composed of a surface antifouling block of poly(sulfobetaine methacrylate) (S) and a subsurface bactericidal block (H(N)) of nitric-oxide-emitting functionalized poly(hydroxyethyl methacrylate) (H) covalently grafted from the inner and outer surfaces of a polyurethane catheter. The block copolymer architecture of the coating is important for achieving good broad-spectrum anti-biofilm activity with good biocompatibility and low fouling. The coating procedure is scalable to clinically useful catheter lengths. Only the block copolymer brush coating ((H(N)-b-S)) shows unprecedented, above 99.99%, in vitro biofilm inhibition of Gram-positive and Gram-negative bacteria, 100-fold better than previous coatings. It has negligible toxicity toward mammalian cells and excellent blood compatibility. In a murine subcutaneous infection model, it achieves >99.99% biofilm reduction of Gram-positive and Gram-negative bacteria compared with <90% for silver catheter, while in a porcine central venous catheter infection model, it achieves >99.99% reduction of MRSA with 5-day implantation. This precision coating is readily applicable for long-term biofilm-resistant and blood-compatible copolymer coatings covalently grafted from a wide range of medical devices.

Original languageEnglish
Pages (from-to)2031-2045
Number of pages15
JournalACS Central Science
Volume6
Issue number11
DOIs
StatePublished - 25 Nov 2020

Fingerprint

Dive into the research topics of 'Precisely Structured Nitric-Oxide-Releasing Copolymer Brush Defeats Broad-Spectrum Catheter-Associated Biofilm Infections in Vivo'. Together they form a unique fingerprint.

Cite this