Skip to main navigation Skip to search Skip to main content

Modeling, Characterization, and Compensation of Detection Errors for Differential Frequency Modulation Whole-Angle Hemispherical Resonator Gyroscope

  • Kaichen Yan
  • , Xiaoxu Wang
  • , Chao Wang
  • , Tianliang Qu
  • , Xi Zhang
  • , Chicheng Che
  • , Junling Zhang
  • , Mingyong Liu
  • , Qianbo Lu
  • Northwestern Polytechnical University Xian
  • Huazhong Optoelectronics Technology Research Institute

Research output: Contribution to journalArticlepeer-review

Abstract

The differential frequency modulation whole-angle (DFM-WA) hemispherical resonator gyroscope (HRG) has lower angular velocity output noise (AVON) than the amplitude modulation WA (AM-WA) HRG, which allows its performance potential to be fully exploited. However, the detection errors comprehensively affect the frequency tracking, amplitude control, and output accuracies of the clockwise (CW) and counterclockwise (CCW) traveling waves, seriously damaging the performance of the DFM-WA HRG. In this article, the detection errors are effectively modeled and characterized in the parametric equations of the two traveling waves as well as the synthesized standing wave, and the accurate identification and compensation of the detection errors are then accomplished based on the angular velocity output (AVO) with low noise. Experimental results strongly indicate that the AVON, the bias instability, and the angle random walk (ARW) of the DFM-WA HRG are reduced by over one magnitude, three times, and five times, respectively, relative to the AM-WA HRG with the same resonator. The DFM-WA scheme gives the HRG an effective scale factor (SF) of 3.057 mHz//s. The SF nonlinearity (SFN) of the DFM-WA HRG is reduced by 69.19% from 2.678 to 0.825 ppm, and its SF stability (SFS) is enhanced by 74.99% from 59.8848 to 14.9792 ppm in the range of −40 C–60 C. The AVO of the DFM-WA HRG is unaffected by ∼1-mHz frequency mismatch and the changes in the CW and CCW traveling wave frequencies within the range of 5003.8–5032 Hz. The DFM-WA scheme is a promising path for the development of the HRG with large dynamics, high precision, low noise, and excellent temperature stability.

Original languageEnglish
Article number9517813
JournalIEEE Transactions on Instrumentation and Measurement
Volume75
DOIs
StatePublished - 2026

Keywords

  • Angle
  • angular velocity output noise (AVON)
  • detection gain
  • differential frequency modulation whole-angle hemispherical resonator gyroscope (DFM-WA HRG)
  • nonlinearity errors
  • scale factor nonlinearity (SFN)
  • SF stability (SFS)

Fingerprint

Dive into the research topics of 'Modeling, Characterization, and Compensation of Detection Errors for Differential Frequency Modulation Whole-Angle Hemispherical Resonator Gyroscope'. Together they form a unique fingerprint.

Cite this