Skip to main navigation Skip to search Skip to main content

Investigation into the influence of blowing ratio and mist parameters on mist-assisted film cooling performance on turbine blade pressure surfaces with representative film holes

  • Lin Li
  • , Tianhao Yong
  • , Cunliang Liu
  • , Zhuchuan Chang
  • , Zhiteng Zhang
  • Xinjiang University
  • Science and Technology on Altitude Simulation Laboratory

Research output: Contribution to journal › Article › peer-review

1 Scopus citations

Abstract

In this study, the numerical simulation method is adopted to investigate the flow and cooling characteristics of gas–liquid two-phase flow through three typical film holes (cylindrical holes, fan-shaped holes, and forward-inclined holes) on the pressure surface of turbine blades. The effects of blowing ratio and mist parameters on adiabatic film cooling effectiveness and droplet flow characteristics are systematically analyzed. The findings indicate that the process of droplet evaporation contributes to a reduction in the coolant temperature, thereby increasing cooling effectiveness by an average of 38.1% compared to pure air cooling. Moreover, increasing the blowing ratio reduces the rate of droplet evaporation while concomitantly raising the number of droplets ejected from the film holes. The fan-shaped holes exhibit a more pronounced enhancement in mist-assisted cooling due to the expansion of the film hole outlet, which reduces jet momentum. The cooling effectiveness decay rate in the proximity of the holes (X/D = 3) is reduced by approximately 80.2%. Compared to the cylindrical and forward-inclined holes, the fan-shaped holes increase cooling effectiveness near the holes (X/D < 5) by approximately 24.1% to 44.4% on average. Additionally, compared to droplet diameter, mist concentration has a more significant impact on the film cooling effectiveness. For each 5% increase in mist concentration, the film cooling effectiveness increases by about 19.7%. The larger-diameter droplets exhibit a reduced evaporation rate but tend to penetrate the cooling film due to inertia effects. However, increasing mist concentration can mitigate the adverse effects of rapid evaporation rates for small-diameter droplets, thereby enhancing cooling effectiveness.

Original languageEnglish
Article number104836
JournalThermal Science and Engineering Progress
Volume77
DOIs
StatePublished - Sep 2026

Keywords

  • Adiabatic film cooling
  • Air-mist coolant
  • Droplet flow characteristics
  • Pressure surface
  • Turbine blade

Fingerprint

Dive into the research topics of 'Investigation into the influence of blowing ratio and mist parameters on mist-assisted film cooling performance on turbine blade pressure surfaces with representative film holes'. Together they form a unique fingerprint.

Cite this