TY - GEN
T1 - Hybrid Positioning and Power Transfer for Capsule Endoscopy with Relay-Based Transmitting Coil
AU - Gao, Chen
AU - Luo, Shiyang
AU - Zhou, Xiaozhou
AU - Zhang, Hao
AU - Guo, Yongxin
N1 - Publisher Copyright:
© 2026 IEEE.
PY - 2026
Y1 - 2026
N2 - A relay-based transmitting (Tx) coil to realize hybrid wireless positioning and power transfer for the wireless capsule endoscopy (WCE) is proposed. The proposed coil configuration is composed of one center-excitation coil and two symmetrically placed relay coils. By parameterization of the coil array and jointly optimization of the variables, the optimum configuration presents a field uniformity of 92.07% and a linearity of 77.56%. In addition, the configuration enables free switching between the uniform field mode for power transfer and the gradient field mode for wireless positioning by simply tuning the compensation capacitance on the coil. In the experiment, the center-to-relay coil current ratio is 0.705 and -1.999 for the uniform field and the gradient field. As a result, the measured field uniformity of 88.07% and the measured linearity of 72.6% validate the effectiveness of the proposed coil configuration. Besides, the gradient of the measured field is 159.7 mV/cm than exceed the resolution requirement of 100 mV/cm. At last, the proposed approach offers a more extensive uniform field and a more linear gradient field than the conventional approach for the WCE application. Index Terms-Wireless capsule endoscopy (WCE), wireless power transfer (WPT), wireless positioning, relay coil, current control.
AB - A relay-based transmitting (Tx) coil to realize hybrid wireless positioning and power transfer for the wireless capsule endoscopy (WCE) is proposed. The proposed coil configuration is composed of one center-excitation coil and two symmetrically placed relay coils. By parameterization of the coil array and jointly optimization of the variables, the optimum configuration presents a field uniformity of 92.07% and a linearity of 77.56%. In addition, the configuration enables free switching between the uniform field mode for power transfer and the gradient field mode for wireless positioning by simply tuning the compensation capacitance on the coil. In the experiment, the center-to-relay coil current ratio is 0.705 and -1.999 for the uniform field and the gradient field. As a result, the measured field uniformity of 88.07% and the measured linearity of 72.6% validate the effectiveness of the proposed coil configuration. Besides, the gradient of the measured field is 159.7 mV/cm than exceed the resolution requirement of 100 mV/cm. At last, the proposed approach offers a more extensive uniform field and a more linear gradient field than the conventional approach for the WCE application. Index Terms-Wireless capsule endoscopy (WCE), wireless power transfer (WPT), wireless positioning, relay coil, current control.
UR - https://www.scopus.com/pages/publications/105053337089
U2 - 10.1109/WPTCE66920.2026.11691196
DO - 10.1109/WPTCE66920.2026.11691196
M3 - 会议稿件
AN - SCOPUS:105053337089
T3 - 2026 IEEE Wireless Power Technology Conference and Expo, WPTCE 2026
BT - 2026 IEEE Wireless Power Technology Conference and Expo, WPTCE 2026
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2026 IEEE Wireless Power Technology Conference and Expo, WPTCE 2026
Y2 - 6 July 2026 through 9 July 2026
ER -