Skip to main navigation Skip to search Skip to main content

Experimental and numerical study of transpiration cooling in an octet-truss array structure

  • Northwestern Polytechnical University Xian
  • Collaborative Innovation Center for Advanced Aero-Engine
  • Science and Technology on Altitude Simulation Laboratory

Research output: Contribution to journal › Article › peer-review

Abstract

To improve thermal protection under high heat flux conditions, this study investigates the flow and heat transfer characteristics of transpiration cooling structures based on octet-truss lattice (OTL) arrays through experiments and numerical simulations. Cooling performance is compared with that of square-pore structures, considering the effects of porosity, blowing ratio, mainstream Reynolds number, and inlet temperatures. Experimental results show that OTL structures achieve higher overall cooling effectiveness at the same porosity, with improvements of 8.99%–11.51% over blowing ratios of 5.12%–20.46%. This enhancement is associated with their larger internal heat transfer area and enhanced coolant–solid heat exchange, although it is accompanied by increased pressure drop. Reducing the porosity from 58.4% to 47.6% increases the cooling effectiveness of the OTL structure by 7.76% at a blowing ratio of 10.23%. Increasing the blowing ratio yields diminishing cooling benefits, whereas increasing the mainstream Reynolds number reduces cooling effectiveness, with a maximum experimental reduction of 9.55% within the tested conditions. Changes in inlet temperatures further reveal that overall cooling effectiveness and absolute wall temperature can exhibit different trends, highlighting the need to consider both quantities when assessing thermal protection. These findings provide insights into the cooling mechanisms of OTL structures and guide transpiration cooling design by considering both cooling effectiveness and flow resistance.

Original languageEnglish
Article number111395
JournalInternational Journal of Thermal Sciences
Volume233
DOIs
StatePublished - Mar 2027

Keywords

  • Flow heat transfer coupling
  • Lattice truss
  • Octet-truss structure
  • Porous medium
  • Transpiration cooling

Fingerprint

Dive into the research topics of 'Experimental and numerical study of transpiration cooling in an octet-truss array structure'. Together they form a unique fingerprint.

Cite this