Abstract
Truncated ribs exhibit favorable heat transfer performance in internal cooling channels. However, their cooling applicability in a semi-open trailing-edge cutback configuration, where shedding vortex effects are pronounced, remains unclear. Taking smooth and continuous straight-rib cutback configurations as references, this study is the first to introduce three truncated rib configurations—namely middle-truncated, side-truncated, and staggered-truncated ribs—into the cutback surface. The pressure-sensitive paint (PSP) and transient thermochromic liquid crystal (TLC) techniques were employed to measure the film cooling effectiveness ( η ) and convective heat transfer coefficient on the cutback surface, respectively, with the latter expressed in terms of the relative Nusselt number ( Nu r ) after nondimensionalization. The net heat flux reduction ( NHFR ) was further adopted to evaluate the overall cooling performance. The results indicate that at blowing ratios ( M ) of 0.25 and 0.50, the staggered-truncated rib configuration improves downstream film coverage compared with the continuous straight-rib cutback, mitigating the adverse effect of continuous ribs on coolant attachment. The differences in area-averaged η between the staggered-truncated configuration and the smooth cutback are only 1.3% and 0.1%, respectively. In contrast, the side-truncated configuration leads to a reduction in η in the far downstream region. When M ≥ 0.75, the η over the cutback surface for all rib configurations approaches unity. The advantage of truncated ribs in heat transfer is only observed at M = 1.00, where the staggered-truncated configuration yields the highest increase in both area-averaged Nu r and NHFR , improving by 8.9% and 4.2%, respectively, compared with the continuous straight-rib configuration. Overall, although truncated ribs have shown potential for heat transfer enhancement in internal cooling channels, they do not exhibit a clear cooling advantage over continuous straight ribs in the semi-open trailing-edge cutback configuration, where the flow is strongly influenced by shedding vortices and intense mixing, under most operating conditions. Therefore, their application should be carefully evaluated in relation to the underlying flow mechanisms. This study represents the first systematic investigation of truncated straight ribs applied to a turbulated trailing-edge cutback configuration, and provides a useful reference for the design of robust trailing-edge cooling structures.
| Original language | English |
|---|---|
| Article number | 132286 |
| Journal | Applied Thermal Engineering |
| Volume | 303 |
| DOIs | |
| State | Published - Aug 2026 |
Keywords
- Experimental measurement
- Film cooling effectiveness
- Heat transfer enhancement
- Trailing edge cutback
- Truncated straight ribs
Fingerprint
Dive into the research topics of 'Experimental analysis of the heat transfer performance of trailing-edge cutback with rib-truncated configurations'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver