Abstract
A charge pump is presented by integrating two identical voltage doublers and a modified rat-race coupler to enable its dual-mode operations: radio-frequency (RF)-to-direct current (dc) power conversion and second-harmonic readout. Due to the property of the modified rat-race coupler, it is able to differentially divide incident RF signals for successive voltage doublers' high-efficiency rectification, and couple second harmonics for readout in two highly isolated channels. Output dc voltages are combined in parallel on a single load resistance for more practicality. Experimental validations are demonstrated by both simulation and measurement with a maximum RF-to-dc power conversion efficiency of 71.3% and −14.2 dBm second-harmonic generation with an incident signal power of 19 dBm. This dual-mode charge pump brings a prospect for antenna alignment in the wireless power transfer system by further exploiting second harmonics.
| Original language | English |
|---|---|
| Pages (from-to) | 146-148 |
| Number of pages | 3 |
| Journal | Electronics Letters |
| Volume | 55 |
| Issue number | 3 |
| DOIs | |
| State | Published - 7 Feb 2019 |
| Externally published | Yes |
Fingerprint
Dive into the research topics of 'Dual-mode charge pump with second-harmonic readout for antenna alignment in wireless power transfer system'. Together they form a unique fingerprint.Cite this