Analysis of uncertainties in two-parameter transient heat transfer measurements with liquid crystal

Research output: Contribution to journalArticlepeer-review

9 Scopus citations

Abstract

This paper introduced a method of measuring heat transfer coefficient and dimensionless heat transfer temperature in transient film cooling measurements with liquid crystal, and through the uncertainties of heat transfer coefficient and dimensionless heat transfer temperature, analyzed the impact of dimensionless main flow temperature and dimensionless secondary flow temperature on two-parameters' uncertainties amplification parameters. The results indicate that, increasing the main flow temperature or increasing the difference between two measurements' secondary flow temperatures will decrease the uncertainties of heat transfer coefficient and dimensionless heat transfer temperature.

Original languageEnglish
Pages (from-to)1945-1951
Number of pages7
JournalHangkong Dongli Xuebao/Journal of Aerospace Power
Volume24
Issue number9
StatePublished - Sep 2009

Keywords

  • Liquid crystal
  • Transient measurements
  • Two-parameter heat transfer
  • Uncertainties