Skip to main navigation Skip to search Skip to main content

An inverse strategy for intervertebral disc repair material to achieve non-expansion effect and similar stiffness to human disc

  • Rui Chen
  • , Shuai Li
  • , Bing Li
  • , Susong Yang
  • , Xiaojun Tan
  • , Jianhao Man
  • , Bo Cao
  • , Qian Sun
  • , Zhirong Liang
  • , Muamer Kadic
  • Kunming University of Science and Technology
  • Beihang University
  • Hebei University of Technology
  • Northwestern Polytechnical University Xian
  • Yangtze River Delta Research Institute of Northwestern Polytechnical University
  • University of Technology of Belfort-Montbéliard

Research output: Contribution to journal › Article › peer-review

Abstract

Human intervertebral disc herniation is a prevalent spinal disorder. Currently, metals and polymers are widely used in disc repair; however, their mechanical properties make it difficult to simultaneously match the stiffness of the disc and achieve non-expansive behavior. Hence, novel disc metamaterials with matching stiffness and a non-expansion effect were fabricated from photosensitive resin (PSR), nylon, and polylactic acid (PLA) via three-dimensional (3D) printing. The metamaterials were then characterized using mechanical and biocompatibility tests. These metamaterials achieve non-expansive behavior by combining hexagonal honeycomb and re-entrant structures. The stiffness and Poisson’s ratio of these metamaterials can be tuned by adjusting their geometric parameters. Theoretical modeling and numerical simulations were conducted to analyze the Poisson’s ratio effect and equivalent stiffness of the metamaterials. The results demonstrate that the metamaterials exhibit a more pronounced non-expansion effect under axial loads than both natural discs and conventional 3D implants. Furthermore, the stiffnesses of the implants fabricated from the metamaterials match those of natural discs, promoting mechanical synergy with adjacent vertebrae. In vitro cell proliferation and viability assays demonstrated that PSR, nylon, and PLA exhibited no cytotoxicity toward human nucleus pulposus cells (HNPCs) and the immortalized human chondrocyte cell line after 1, 3, 5 and 7 days of incubation. Cell viability remained above 98% across all tested conditions. Furthermore, calcein acetoxymethyl ester/propidium iodide double-staining tests confirmed the biocompatibility of the metamaterials.

Original languageEnglish
Article number114361
JournalInternational Journal of Solids and Structures
Volume342
DOIs
StatePublished - 1 Jan 2027
Externally publishedYes

Keywords

  • Human disc repair
  • Matching stiffness
  • Mechanical metamaterials
  • Non-expansion effect

Fingerprint

Dive into the research topics of 'An inverse strategy for intervertebral disc repair material to achieve non-expansion effect and similar stiffness to human disc'. Together they form a unique fingerprint.

Cite this