Ablation resistance of ZrC-based composite coating with multi-layer structure for carbon/carbon composites above 2200 °C

  • Yunyu Li
  • , Yichen Liu
  • , Chen Guo
  • , Yibin Chen
  • , Junhao Liang
  • , Jian Zhang
  • , Jiaping Zhang
  • , Lingjun Guo
  • Northwestern Polytechnical University Xian
  • Xi'an Polytechnic University

Research output: Contribution to journalArticlepeer-review

19 Scopus citations

Abstract

The realization of the functionalized design of the coating is an effective measure to improve the ablation resistance of the coating. ZrC-based composite with multi-layer structure coating was designed and successfully prepared on the surface of SiC coated C/C composites. The ablation resistance of coating under different ablation times was evaluated. Results show that although the integrity of the coating was destroyed, the area close to the substrate still maintains a dense structure with the extension of ablation time. The coating could protect C/C composites against ablation for 240 s under the harsh ablation environments with temperature above 2200 ℃.

Original languageEnglish
Article number110600
JournalCorrosion Science
Volume207
DOIs
StatePublished - Oct 2022
Externally publishedYes

Keywords

  • Ablation resistance
  • Ablation times
  • C/C composites
  • Plasma spraying
  • ZrC-based coating

Fingerprint

Dive into the research topics of 'Ablation resistance of ZrC-based composite coating with multi-layer structure for carbon/carbon composites above 2200 °C'. Together they form a unique fingerprint.