Skip to main navigation Skip to search Skip to main content

A strategy for mitigating irradiation-induced interfacial swelling mismatch in C/SiC composites via CNT-modified interphases

  • Qing Chang
  • , Bo Huang
  • , Surui Xia
  • , Yi Yao
  • , Feiyang Pu
  • , Qing Zhang
  • , Fang Ye
  • , Chidong Liu
  • , Laifei Cheng
  • , Xiaoling Sun
  • Northwestern Polytechnical University Xian
  • China Aerospace Science and Technology Corporation

Research output: Contribution to journal › Article › peer-review

Abstract

Irradiation-induced swelling mismatch at the fiber/matrix interface is a critical factor affecting the structural stability of C/SiC composites in nuclear environments. In this work, a carbon nanotube (CNT)-modified interphase is designed to alleviate the irradiation-induced swelling mismatch in C/SiC composites. The swelling behavior and interfacial response of the CNT-modified pyrolytic carbon (PyC) interphase are systematically investigated and compared with those of a conventional PyC interphase following 5 MeV Xe ion irradiation at room and elevated temperatures using atomic force microscopy, Raman spectroscopy, and transmission electron microscopy. The results demonstrate that carbon fibers undergo significantly greater irradiation-induced swelling than the SiC matrix, leading to a pronounced swelling mismatch at the fiber/matrix interface. The introduction of in situ grown CNTs effectively mitigates this mismatch by constructing a three-dimensional compliant interphase that enhances interfacial strain accommodation. As a result, the radial stress developed within the CNT-modified PyC interphase is substantially lower than that in the conventional PyC interphase. These findings provide new insights into the interphase design of radiation-tolerant C/SiC composites for advanced nuclear energy applications.

Original languageEnglish
Article number115782
JournalVacuum
Volume255
DOIs
StatePublished - Jan 2027

Keywords

  • C/SiC composites
  • CNTs
  • Ion irradiation
  • Microstructure evolution

Fingerprint

Dive into the research topics of 'A strategy for mitigating irradiation-induced interfacial swelling mismatch in C/SiC composites via CNT-modified interphases'. Together they form a unique fingerprint.