Skip to main navigation Skip to search Skip to main content

种双标样多谱线校正的 LIBS 定量检测新方法

Translated title of the contribution: Novel LIBS Quantitative Detection Method with Multi-Line Calibration Using Two Standard Samples
  • Shilei Xiong
  • , Dan Feng
  • , Nan Ma
  • , Yuanbin Wang
  • , Ming Luo
  • Northwestern Polytechnical University Xian

Research output: Contribution to journal › Article › peer-review

Abstract

Objective Precise control of metallurgical composition is essential for ensuring metal materials possess superior strength, toughness, and corrosion resistance. Enhancing in-situ composition analysis capabilities is crucial for advancing high-quality, intelligent, and green development in the metallurgical industry. Laser-induced breakdown spectroscopy (LIBS) technology, as an emerging metallurgical composition analysis technique, is widely applied in the field of metallurgical composition analysis of metals. In quantitative LIBS analysis methods, the standard curve method, standard addition method, and AI-based quantitative LIBS analysis all require the prior acquisition of multiple standard samples and knowledge of their elemental contents to conduct research. In scenarios such as industrial online analysis and field testing where preparing and obtaining large quantities of standard samples is challenging, these methods struggle to effectively determine the elemental content of unknown samples. In recent years, calibrationfree laser-induced breakdown spectroscopy (CF-LIBS) technology has developed rapidly, evolving into various variants, which have made significant contributions to improving the quantitative accuracy of CF-LIBS technology. Notably, there is a relatively simple calibration-free detection method known as the one-point and multi-line laser-induced breakdown spectroscopy correction (OP-MLC) method. However, this method’s quantitative accuracy is far inferior to that of traditional CF-LIBS methods. Therefore, developing a correction algorithm to enhance the quantitative accuracy of this method is highly necessary. Methods This study proposes a novel quantitative analysis method for laser-induced breakdown spectroscopy based on two-standard-sample multi-spectral line correction (TSS-MLC). Under the assumptions that basic stoichiometric ablation occurs and the plasma satisfies optical thinness and local thermodynamic equilibrium (LTE), this method improves upon the traditional OP-MLC-LIBS method to further enhance the accuracy of metallurgical composition quantification. In this work, the four elements Mn, Cr, Mo, and Ni in six alloy steel standard samples are selected as detection targets to validate the method’s effectiveness. First, raw LIBS spectral data for these six samples are acquired using an experimental LIBS detection setup. Multiple spectral lines are selected by cross-referencing the NIST database and pre-obtained pure element spectral lines. Next, the first and second standard calibration samples are randomly selected. Using the actual spectral intensity of the first standard calibration sample as the baseline, the deviation between the theoretical and actual spectral intensities of the second standard calibration sample is calculated. Correction factors for the intensities of multiple spectral lines are then derived, enabling the calculation of theoretical spectral intensities for each line in the test samples. Finally, the content of the target element is calculated by establishing a calibration curve based on the theoretical spectral intensities of each spectral line. Results and Discussions The results indicate that the TSS-MLC-LIBS method significantly improves calibration curve performance compared to the OP-MLC-LIBS method. For the same element, the coefficient of determination R2 of the OP-MLC-LIBS calibration curve exhibits significant variation. Taking Mn, Cr, and Ni as examples, the R2 values of the calibration curves fitted to the sample with the lowest elemental content are 0.86443, 0.82663, and 0.77518, respectively, with not all R2 values exceeding 0.9. However, after calibration using the TSS-MLC-LIBS method, the R2 value of the calibration curve for the S6 sample with the lowest Mn content increases from 0.86443 to 0.97887. The R2 value of the calibration curve for the S1 sample with the lowest Cr content increases from 0.82663 to 0.87783. The R2 value of the calibration curve for the S1 sample with the lowest Ni content rises from 0.77518 to 0.96949. Concurrently, the quantitative prediction results of the TSS-MLC-LIBS method increasingly approach the certified content, with significantly enhanced prediction accuracy. The improvement rates in quantitative prediction accuracy for the four elements are 17.41%, 11.25%, 24.17%, and 13.72%, respectively. The relative standard deviation (RSD) of the four elements predicted by the TSS-MLC-LIBS method is significantly lower than that of the OP-MLC-LIBS method in most cases, with the average relative standard deviation (ARSD) decreasing by 70.97%, 25.29%, 62.58%, and 53.54%, respectively. This fully demonstrates that the method can effectively reduce the uncertainty of element content predictions. Conclusions The TSS-MLC-LIBS method is primarily an improvement upon the OP-MLC-LIBS approach. By introducing a second standard calibration sample, it enables rapid calculation of the deviation between theoretical and actual spectral intensities. This further allows for the computation of correction factors for multiple spectral line intensities, subsequently determining the theoretical spectral intensity of each line in the test sample and establishing a calibration curve. Compared to the traditional OP-MLC-LIBS method, this novel approach further enhances quantitative analysis accuracy and reduces uncertainty in quantitative predictions. Simultaneously, it avoids overly complex computational processes, significantly streamlining calculations. Its flexible and straightforward advantages provide valuable methodological reference for quantitative LIBS research.

Translated title of the contributionNovel LIBS Quantitative Detection Method with Multi-Line Calibration Using Two Standard Samples
Original languageChinese (Traditional)
Article number1811002
JournalZhongguo Jiguang/Chinese Journal of Lasers
Volume53
Issue number18
DOIs
StatePublished - Sep 2026

Fingerprint

Dive into the research topics of 'Novel LIBS Quantitative Detection Method with Multi-Line Calibration Using Two Standard Samples'. Together they form a unique fingerprint.

Cite this