Skip to main navigation Skip to search Skip to main content

旋流入口条件下燃烧室隔热屏环型气膜孔冷却效果研究

Translated title of the contribution: Cooling performance of annular air film hole of combustion chamber heat shield under swirl inlet condition
  • Xiaohui Bai
  • , Zhongyao Zhang
  • , Cheng Ao Duan
  • , Song Fu
  • , Cunliang Liu
  • , Xianlong Meng
  • Northwestern Polytechnical University Xian
  • Science and Technology on Altitude Simulation Laboratory
  • National Key Laboratory of Science and Technology on Advanced Light-duty Gas-turbine

Research output: Contribution to journal › Article › peer-review

Abstract

To improve the film cooling effectiveness of combustor heat shield walls under swirling flow con⁃ ditions,this study proposes an annular film-cooling hole design,which increases the spanwise chord length and circumferential exit area of the hole to counteract the strong swirling flow’s sweeping and entrainment effects. Nu⁃ merical simulations were conducted to comparatively analyze the film cooling performance of annular holes and cylindrical holes,revealing the influence mechanisms of different aerodynamic and structural parameters on an⁃ nular holes. The variation in film cooling characteristics of annular holes under different inflow conditions was in⁃ vestigated,clarifying the impact of aspect-to-width ratio on their cooling performance. The results indicate that the annular hole design exhibits superior wall attachment and broader spanwise film coverage after coolant ejec⁃ tion. Compared to cylindrical holes,the film cooling effectiveness of annular holes shows significant improve⁃ ment,with the enhancement becoming more pronounced at higher blowing ratios. The maximum improvement reaches 64.6% under uniform inflow and 10.21% under swirling inflow. Increasing the inclination angle of film-cooling holes can enhance the adherence of the coolant flow to the swirling wall,thereby significantly improving the cooling effectiveness near the hole exit. However,this configuration also diminishes the synergistic cooling in⁃ teraction between adjacent annular film-cooling holes. When the aspect-to-width ratio increases,the overall air film coverage and adhesion effect of the annular hole are enhanced,but the superposition of the air film between the small pores inside the unit annular hole will be weakened. The optimal aspect-to-width ratio range for achiev⁃ ing the best film cooling effectiveness of annular holes on swirling flow-affected walls is determined to be 3.1~4.2.

Translated title of the contributionCooling performance of annular air film hole of combustion chamber heat shield under swirl inlet condition
Original languageChinese (Traditional)
Article number202506019
JournalTuijin Jishu/Journal of Propulsion Technology
Volume47
Issue number9
DOIs
StatePublished - 10 Sep 2026

Fingerprint

Dive into the research topics of 'Cooling performance of annular air film hole of combustion chamber heat shield under swirl inlet condition'. Together they form a unique fingerprint.

Cite this